Xilinx DPD solution experience (4)

The Microblaze of the Xilinx DPD solution returns a CommandStatus every time Control_mode is executed (commonly speaking, it is a command).

I use the CommandStatus that I often use and encountered, for your reference. Below are the format descriptions for the various CommandStatuss.

DPDCommandStatus code : the meaning of the representative
1 : Microblaze is busy and still executing the last Control_mode
2: The command was executed successfully.
3: 16-bit overflow occurs when the DPD pre-distortion coefficient calculated by the ECF is converted to the LUT
255 : ECF update DPD predistortion coefficient detected PA overload, still using updated coefficient
256: ECF update DPD predistortion coefficient detects PA overload, abandoning the use of updated coefficients
-1 : Control_mode command is invalid
-112 : The currently selected channel is invalid
-113 : DPD capture sampling is unsuccessful
-114 : Insufficient amount of sampled data during ECF runtime
-115 : An illegal value occurs when the ECF runs the LS algorithm (for example, the dividend is 0)
-120 : TX_PATH and RX_PATH sample data cannot be aligned
-124 : The measurement length of Power_Meter configured for ECF is too long, out of range
-125 : The minimum delay value configured for ECF exceeds the maximum delay value
-126 : The number of sampling points allocated to the ECF is outside the allowable range.
-127 : The number of polynomials configured for ECF is out of the allowable range.
-128 : The number of memory items allocated to the ECF is out of the allowable range.
-254 : The average number of blocks allocated to QMC is outside the allowable range.
-255 : The number of sampling points configured for QMC is invalid.

These CommandStatuss are provided to provide you with a quick lookup table. Very convenient! I wish you all a happy use of this DPD.

Power Meter Socket

Power Meter is a monitoring and testing instrument which determines the power consumption of a connected appliance and the cost of the electricity consumed.
Built-in 3.6V rechargeable Batteries ( . The purpose of the batteries is to store the total electricity and memory setting
Resetting
If an abnormal display appears or the buttons produce no response, the instrument must be reset. To do this,
press the RESET button.
Display Mode
Entire LCD can be displayed for about 1 minute and then it automatically gets into Model. To transfer from
one mode to the other, press the FUNCTION button.
Mode 1: Time/Watt/Cost Display Display duration(how long) this device connect to power source.LCD on first line shows 0:00 with first two figures mean minutes(2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:00 again with first two numbers meas hour(2 figures will occur at 10hours)and the rest shows minutes. The rest can be done in the same manner which means after 24 hours, it will re-caculate. LCD on second line displays current power which ranges in 0.0W 〜 9999W. LCD on third line displays the current electricity costs which ranges in O.Ocost 〜 9999cost. It will keep on O.OOcost before setting rate without other figures.
Mode 2: Time/Cumulative electrical quantity Display Display duration(how long) this device connect to power source.
LCD on first line shows 0:00 with first two figures mean minutes(2 figures will occur while occur at 10 min) and the rest shows seconds. After 60mins, it displays 0:00 again with first two numbers meas hour(2 figures will occur at 10hours)and the rest shows minutes. The rest can be done in the same manner which
means after 24 hours, it will re-caculate. LCD on second line displays current cumulative electrical quantity which ranges in 0.000KWH 〜 9999KWH without other figures. LCD on third line displays"DAY"- "1 'Will be showed on numerical part(the other three figures will be showed at carry) which means it has cumulated electrical quantity for 24hours(one day). The rest can be done in the same manner untill the maximal cumulative time of 9999 days.
Mode 3: TimeA^bltage/Frequency Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays current voltage supply (v) which ranges in 0.0V 〜 9999V .LCD on third line displays current frequency (HZ) which ranges in 0.0HZ 〜 9999Hz without other figures.
Mode 4: Time/Current/Power Factor Display LCD on first line displays the same as Mode 1 dones.LCD on second line displays load current which ranges in 0.0000A 〜 9999A. LCD on third line displays current power factor which ranges in 0.00PF 〜 LOOPF without other figures.
Mode 5:Time/Minimum Power Display LCD on first line displays the same as Mode 1 dones. LCD on
second line displays the minimum power which ranges in 0.0W 〜 9999W. LCD on third line displays character of "Lo" without other figures.
Mode 6: Time/Maximal Power Display LCD on first line displays the same as Mode 1 dones. LCD on second line displays the maximal power which ranges in 0.0W 〜 9999W. LCD on third line displays character of "Hi" without other figures.
Mode 7: Time/Price Display LCD on first line displays the same as Mode 1 dones. LCD on third line displays the cost which ranges in O.OOCOST/KWH 〜 99.99COST/KWH without other figures.
Overload Display: When the power socket connects the load over 3680W, LCD on second line displays the''OVERLOAD[ with booming noise to warn the users, (selectable choice)
Supplemental informations:
1: Except [OVERLOAD[ interface, LCD on first line display time in repitition within 24hours.
2: LCD on first line, second line or third line described in this intruction take section according to two black lines on LCD screen. Here it added for clarified purpose.
3. Mode 7 will directly occur while press down button "cost".
4. [UP"&"Down" are in no function under un-setting mode.
Setting Mode
1. Electricity price setting
After keeping COST button pressed lasting more than 3 seconds(LCD on third line display system defaults price, eg O.OOCOST/KWH ),the rendered content begins moving up and down which means that the device
has entered the setting mode. After that, press FUNCTION for swithing , then press "UP"and "DOWN" button again to set value which ranges in OO.OOCOST/KWH 〜 99.99COST/KWH. After setting all above, press COST to return to Mode7 or it will automatically return to Mode7 without any pressing after setting with data storage.

Power meter socket, Energy meter socket, Energy meter cost socket, Power meter cost socket, Energy power meter socket

NINGBO COWELL ELECTRONICS & TECHNOLOGY CO., LTD , https://www.cowellsocket.com

Posted on